3 CONDUCTOR
3 CONDUCTOR COPPER WIRE GUAGE SIZE
WATTS PER
FIXTURE
# of
FIXTURES
VOLTS
APPROX.
AMPS
#14
#12
#10
#8
#6
#4
#2
75
2
120
1.3
740
1150
1920
2955
4710
7445
11535
75
3
120
1.9
505
790
1315
2025
3220
5090
7895
75
4
120
2.5
385
600
1000
1535
2445
3870
6000
75
6
120
3.8
255
395
655
1010
1610
2545
3945
75
8
120
5
190
300
500
765
1220
1935
3000
150
2
120
2.5
385
600
1000
1535
2445
3870
6000
150
3
120
3.8
255
395
655
1010
1610
2545
3945
150
4
120
5
190
300
500
765
1220
1935
3000
150
6
120
7.5
125
200
330
510
815
1290
2000
150
8
120
10
---
150
250
380
610
965
1500
250
2
120
4.2
230
355
595
915
1455
2300
3570
250
3
120
6.3
150
235
395
610
970
1535
2380
250
4
120
8.5
110
175
290
450
720
1135
1760
250
6
120
12.5
---
120
200
305
485
770
1200
250
8
120
17
requires 2 runs of cable
2 runs of cable required at:
110
175
290
450
720
1135
1760
500
3
120
12.5
---
120
200
305
485
770
1200
500
4
120
17
requires 2 runs of cable
2 runs of cable required at:
110
175
290
450
720
1135
1760
500
6
120
25
requires 2 runs of cable
2 runs of cable required at:
---
120
200
305
485
770
1200
500
8
120
34
requires 2 runs of cable
2 runs of cable required at:
---
85
145
225
360
570
880
AquaMaster® recommends consulting a licensed electrician to properly size any underground cable from the main power source to our control panel. Please contact AquaMaster® if assistance is required.
Maximum Recommended Length from Fountain Lights to Control Panel for
Masters Series®, Classic Series and Celestial Fountains®
FEATURES 60Hz CABLE SIZING
  50Hz CABLE SIZING
16024 CTH X KIEL, WI 53042 USA PH 920-693-3121 FX 920-693-3634