SINGLE PHASE 3 CONDUCTOR
3 CONDUCTOR COPPER WIRE GAUGE SIZE
UNIT
VOLTS
APPROX. AMPS
#14
#12
#10
#8
#6
#4
#2
1/2 HP
120
5
175
275
450
700
1120
1770
2750
1/2 HP
208-240
2.5
670
1040
1730
2660
4240
6710
10400
4 CONDUCTOR: REQUIRED ON ALL 1 - 10 HP SINGLE PHASE & THREE PHASE AERATORS
SINGLE PHASE 4 CONDUCTOR
4 CONDUCTOR COPPER WIRE GAUGE SIZE
UNIT
VOLTS
APPROX. AMPS
#14
#12
#10
#8
#6
#4
#2
1 HP
120
18
---
---
125
195
310
490
760
1 HP
208-240
9
---
285
480
740
1170
1860
2880
2 HP
208-240
12
---
210
360
550
880
1395
2165
3.5 HP
208-240
15
---
---
285
440
700
1115
1730
5.5 HP
208-240
26
---
---
165
250
400
645
1000
SINGLE PHASE 4 CONDUCTOR
4 CONDUCTOR COPPER WIRE GAUGE SIZE
UNIT
VOLTS
APPROX. AMPS
#14
#12
#10
#8
#6
#4
#2
1 HP
208-240
5
---
600
1000
1540
2450
3870
6000
1 HP
440-480
2.5
---
2540
4230
6510
10360
16390
25400
2 HP
208-240
6
---
500
830
1280
2040
2325
5000
2 HP
440-480
3
---
2115
3525
5425
8640
13655
21170
3 HP
208-240
10
---
300
500
770
1225
1935
3002
3 HP
440-480
5
---
1270
2115
3250
5185
8195
12700
5 HP
208-240
12
---
250
415
640
1020
1610
2500
5 HP
440-480
6
---
1060
1760
2710
4320
6825
10585
AquaMaster® recommends consulting a licensed electrician to properly size
any underground cable from the main power source to our control panel.
Please contact AquaMaster® if assistance is required.
*Actual voltage to motor will affect
  your fountain’s performance.
Return to Classic Cad-Specs-Details